5.Technical Data

Gas Burners Rating
Rapid Burner

2,1 kW (GPL) - 2,3 kW (GZ 50/GZ 35)

Semirapid Burner

1,5 kW (GPL) - 1,6 kW (GZ 50/GZ 35)

Auxiliary Burner

0,7 kW

Category

II /II-35, 50, III-X-I-Zt

Setting

Natural Gas GZ 50 20 mbar

Gas connection

G 1/2"

Electric Supply

230 V 50 Hz

HOB RECESS
DIMENSIONS

Length

560 mm.

Width

480 mm.

6.Instruction for the Installer

l The following instructions about installation and

maintenance must be carried out by qualified

personnel in compliance with the regulation in

force.

l The side walls of the unit in which the hob is

going to be installed, must not exceed the height

of the working top.

l Avoid installing the appliance in the proximity of

inflammable materials (e.g. curtains, tea towels

etc.).

l The appliance must be electrically disconnected

before all interventions. If any electric supply to

the appliance is required to carry out the work,

ensure all the necessary precautions are followed.

GAS CONNECTION

Choose fixed connections or use a flexible pipe in

stainless steel.

If using flexible metallic pipes, be careful they do not

come in contact with mobile parts or they are not

squeezed. Use the same attention when the hob is

combinated with an oven.

IMPORTANT - To ensure a correct operation, a saving

of energy and the long-life of the appliance, the voltage

pressure of the appliance must correspond to the

recommended values.

The adjustable connection is fixed to the comprehensive

ramp by means of a threaded nut GJ 1/2". Interpose the

sealing between the components as shown in fig. 4.

Screw the parts without forcing, adjust the connection in

the required direction and tighten everything.

IMPORTANT - When the final connection has been

made, it is essential that a thorough leak test is carried

out on the hob and installation. Use some soapy water,

never a flame.

A) Ramp with ending nut

B) Seal

C) Adjustable connection

Fig. 4