VLC Troubleshooting

This chapter covers potential problems and possible remedies. After each problem description,
some steps are provided to help you to diagnose and solve the problem.

3.1 The SYS or PWR LED Does Not Turn On

3.2 The ALM LED Is On

The ALM (alarm) LED lights when the line card is overheated or the voltage readings are
outside the tolerance levels.

Table 9 SYS LED Troubleshooting

STEPS

CORRECTIVE ACTION

1

Make sure the power wires are properly connected to the power supply and the power

supply is operating normally. Make sure you are using the correct power source (refer to

the IES User’s Guide for details).

2

Make sure the power wires are connected properly.

3

Make sure the line card is properly installed.

4

The LED itself or the unit may be faulty; contact your vendor.

Table 10 ALM LED Troubleshooting

STEPS

CORRECTIVE ACTION

1

Use the

sys

monitor show

command to verify the cause of the alarm. See step 2 if the

unit is overheated, and step 3 if the voltages are out of the allowed ranges.

2

Ensure that the IES is installed in a well-ventilated area and that normal operation of the

fans is not inhibited. Keep the bottom, top and all sides clear of obstructions and away from

the exhaust of other equipment.

3

If the voltage levels are outside the allowed range, take a screen shot of the

sys

monitor show

command display and contact your vendor.