beautypg.com

Delay l,c,r, Delay l,r, Cross delay – Yamaha DB50XG User Manual

Page 40: Early ref1,2, Gate reverb,reverse gate, White room ,tunnel, basement, Echo

background image

39

: Can be controlled by AC1 (Assignable Controller 1)

• No. *

: These numbers correspond to the Parameter Suffix numbers in (page 27)

P42** : Refer to “Effect Data Assign Table”

Effect Parameter List / Liste des paramètres d’effet

1

Lch Delay

0.1~715.0ms

1-7150

2

Rch Delay

0.1~715.0ms

1-7150

3

Cch Delay

0.1~715.0ms

1-7150

4

Feedback Delay

0.1~715.0ms

1-7150

5

Feedback Level

-63~+63

1-127

6

Cch Level

0~127

0-127

7

High Damp

0.1~1.0

1-10

8

9

10

Dry/Wet

D63>W ~ D=W ~ D

1-127

11

12

13

EQ Low Frequency

50Hz~2.0kHz

8-40

table#3

14

EQ Low Gain

-12~+12dB

52-76

15

EQ High Frequency

500Hz~16.0kHz

28-58

table#3

16

EQ High Gain

-12~+12dB

52-76

No. * Parameter

Range

Value

P42**

Control

DELAY L,C,R

1

Lch Delay

0.1~715.0ms

1-7150

2

Rch Delay

0.1~715.0ms

1-7150

3

Feedback Delay 1

0.1~715.0ms

1-7150

4

Feedback Delay 2

0.1~715.0ms

1-7150

5

Feedback Level

-63~+63

1-127

6

High Damp

0.1~1.0

1-10

7

8

9

10

Dry/Wet

D63>W ~ D=W ~ D

1-127

11

12

13

EQ Low Frequency

50Hz~2.0kHz

8-40

table#3

14

EQ Low Gain

-12~+12dB

52-76

15

EQ High Frequency

500Hz~16.0kHz

28-58

table#3

16

EQ High Gain

-12~+12dB

52-76

No. * Parameter

Range

Value

P42**

Control

DELAY L,R

1

L->R Delay

0.1~355.0ms

1-3550

2

R->L Delay

0.1~355.0ms

1-3550

3

Feedback Level

-63~+63

1-127

4

Input Select

L,R,L&R

0-2

5

High Damp

0.1~1.0

1-10

6

7

8

9

10

Dry/Wet

D63>W ~ D=W ~ D

1-127

11

12

13

EQ Low Frequency

50Hz~2.0kHz

8-40

table#3

14

EQ Low Gain

-12~+12dB

52-76

15

EQ High Frequency

500Hz~16.0kHz

28-58

table#3

16

EQ High Gain

-12~+12dB

52-76

No. * Parameter

Range

Value

P42**

Control

CROSS DELAY

1

Type

S-H, L-H, Rdm, Rvs, Plt, Spr

0-5

2

Room Size

0.1~7.0

0-44

table#6

3

Diffusion

0~10

0-10

4

Initial Delay

0~63

0-63

table#5

5

Feedback Level

-63~+63

1-127

6

HPF Cutoff

Thru~8.0kHz

0-52

7

LPF Cutoff

1.0k~Thru

34-60

8

9

10

Dry/Wet

D63>W ~ D=W ~ D

1-127

11

Liveness

0~10

0-10

12

Density

0~3

0-3

13

High Damp

0.1~1.0

1-10

14

15

16

No. * Parameter

Range

Value

P42**

Control

EARLY REF1,2

1

Type

TypeA,TypeB

0-1

2

Room Size

0.1~7.0

0-44

table#6

3

Diffusion

0~10

0-10

4

Initial Delay

0~63

0-63

table#5

5

Feedback Level

-63~+63

1-127

6

HPF Cutoff

Thru~8.0kHz

0-52

7

LPF Cutoff

1.0k~Thru

34-60

8

9

10

Dry/Wet

D63>W ~ D=W ~ D

1-127

11

Liveness

0~10

0-10

12

Density

0~3

0-3

13

High Damp

0.1~1.0

1-10

14

15

16

No. * Parameter

Range

Value

P42**

Control

GATE REVERB,REVERSE GATE

1

Reverb Time

0.3~30.0s

0-69

table#4

2

Diffusion

0~10

0-10

3

Initial Delay

0~63

0-63

table#5

4

HPF Cutoff

Thru~8.0kHz

0-52

table#3

5

LPF Cutoff

1.0k~Thru

34-60

table#3

6

7

8

9

10

Dry/Wet

D63>W ~ D=W ~ D

1-127

11

Rev Delay

0~63

0-63

table#5

12

Density

0~3

0-3

13

Er/ Rev Balance

E63> R~ E=R ~ E

1-127

14

15

Feedback Level

-63~+63

1-127

16

No. * Parameter

Range

Value

P42**

Control

HALL1,2, ROOM1,2,3 ,STAGE1,2, PLATE

1

Reverb Time

0.3~30.0s

0-69

table#4

2

Diffusion

0~10

0-10

3

Initial Delay

0~63

0-63

table#5

4

HPF Cutoff

Thru~8.0kHz

0-52

table#3

5

LPF Cutoff

1.0k~Thru

34-60

table#3

6

Width

0.5~10.2m

0-37

table#8

7

Height

0.5~20.2m

0-73

table#8

8

Depth

0.5~30.2m

0-104

table#8

9

Wall Vary

0~30

0-30

10

Dry/Wet

D63>W ~ D=W ~ D

1-127

11

Rev Delay

0~63

0-63

table#5

12

Density

0~3

0-3

13

Er/ Rev Balance

E63> R ~ E=R ~ E

1-127

14

15

Feedback Level

-63~+63

1-127

16

No. * Parameter

Range

Value

P42**

Control

WHITE ROOM ,TUNNEL, BASEMENT

1

Lch Delay1

0.1~355.0ms

1-3550

2

Lch Feedback Level

-63~+63

1-127

3

Rch Delay1

0.1~355.0ms

1-3550

4

Rch Feedback Level

-63~+63

1-127

5

High Damp

0.1~1.0

1-10

6

Lch Delay2

0.1~355.0ms

1-3550

7

Rch Delay2

0.1~355.0ms

1-3550

8

Delay2 Level

0~127

0-127

9

10

Dry/Wet

D63>W ~ D=W ~ D

1-127

11

12

13

EQ Low Frequency

50Hz~2.0kHz

8-40

table#3

14

EQ Low Gain

-12~+12dB

52-76

15

EQ High Frequency

500Hz~16.0kHz

28-58

table#3

16

EQ High Gain

-12~+12dB

52-76

No. * Parameter

Range

Value

P42**

Control

ECHO

: Peut être contrôlé par AC1 (Assignable Controller 1)

• No. *

: Ces numéros correspondent au numéros Parameter Suffix dans le (page 27)

P42** : Cf. le “Tableau d’assignation de valeur de données d’effet”