Table 6: bq heating capacities – York BQ 036 User Manual
Page 19
036-21508-005-A-0305
Unitary Products Group
19
TABLE 6: BQ HEATING CAPACITIES
CAP
& KW
-10
0
10
20
30
40
50
60
MBH
13.1
16.4
23.5
29.1
30.2
41.7
47
48.2
KW
2.9
3
3.2
3.3
3.5
3.7
3.8
3.9
MBH
11.9
15
21.5
26.7
27.7
38.2
43.1
44.1
KW
3
3.1
3.4
3.4
3.6
3.8
3.9
4.1
MBH
10.9
13.6
19.6
24.3
25.2
34.8
39.3
40.2
KW
3.1
3.2
3.4
3.5
3.8
3.9
4.1
4.2
MBH
12.4
15.5
22.5
27.7
28.7
39.6
44.7
45.8
KW
2.7
2.9
3
3.1
3.3
3.5
3.6
3.7
MBH
11.4
14.1
20.3
25.2
26.1
36.1
40.7
41.6
KW
2.9
3
3.2
3.3
3.5
3.7
3.8
3.9
MBH
10.4
13.1
18
23.2
24.2
33.3
37.6
38.5
KW
3
3.1
3.2
3.4
3.6
3.8
3.9
4
MBH
11.8
14.8
21.3
26.5
27.5
37.8
42.7
43.7
KW
2.7
2.8
3
3.1
3.3
3.4
3.5
3.6
MBH
10.8
13.5
19.4
24
24.9
34.4
38.8
39.7
KW
2.9
3
3.1
3.3
3.4
3.6
3.7
3.8
MBH
9.9
12.4
17.8
22
22.9
31.5
35.6
36.5
KW
2.9
3.1
3.2
3.4
3.5
3.7
3.8
3.9
MBH
11.2
14.1
20.3
25.2
26.1
35.9
40.6
41.6
KW
2.6
2.7
2.9
3
3.3
3.3
3.5
3.5
MBH
10.2
12.8
18.5
22.8
23.6
32.7
36.9
37.8
KW
2.8
2.9
3
3.2
3.3
3.5
3.6
3.7
MBH
9.3
11.7
16.7
20.7
21.5
29.8
33.6
34.4
KW
2.8
3
3.1
3.3
3.4
3.6
3.7
3.8
MBH
12.3
17.3
22.5
28.2
36.3
44.5
53.8
61.6
KW
3.4
3.5
3.6
3.6
3.8
4
4.6
5.2
MBH
11.8
16.6
21.6
27.1
34.9
42.8
51.7
59.2
KW
3.5
3.6
3.8
3.8
4
4.2
4.8
5.4
MBH
10.9
15.3
19.9
24.9
32.1
39.4
47.6
54.5
KW
3.6
3.7
4
4
4.1
4.4
5
5.7
MBH
12.1
17
22
27.7
34.5
42.3
51.2
58.6
KW
3.3
3.4
3.5
3.6
3.6
3.8
4.4
5
MBH
11.6
16.3
21.2
26.6
33.2
40.7
49.2
56.3
KW
3.4
3.5
3.6
3.7
3.8
4
4.6
5.2
MBH
10.7
15
19.5
24.5
30.5
37.4
45.3
51.8
KW
3.5
3.6
3.8
3.9
4
4.2
4.8
5.4
MBH
10.9
15.3
19.9
24.9
31.7
38.9
47
53.8
KW
3.1
3.2
3.3
3.4
3.5
3.7
4.2
4.8
MBH
10.5
14.7
19.1
24
30.5
37.4
45.2
51.7
KW
3.2
3.3
3.4
3.5
3.6
3.8
4.4
5
MBH
9.6
13.5
17.6
22
28.1
34.4
41.6
47.6
KW
3.3
3.4
3.5
3.6
3.8
4
4.6
5.2
MBH
18.2
24.7
31.1
38.4
45.6
55.4
64.7
75.6
KW
5
5.1
5.2
5.3
5.3
5.6
5.9
6.5
MBH
17.5
23.7
29.9
37
43.9
53.3
62.2
72.7
KW
5.2
5.3
5.4
5.5
5.6
5.9
6.2
6.8
MBH
16.1
21.8
27.5
34
40.4
49
57.2
66.9
KW
5.4
5.6
5.7
5.8
5.9
6
6.5
7.2
MBH
18
24.4
30.8
38.1
45
54.7
63.9
74.7
KW
4.7
4.8
4.9
5
5.3
5.5
5.8
6.4
MBH
17.3
23.5
29.6
36.6
43.3
52.6
61.4
71.8
KW
4.9
5
5.1
5.2
5.5
5.8
6.1
6.7
MBH
15.9
21.6
27.2
33.7
39.8
48.4
56.5
66.1
KW
5.1
5.3
5.4
5.5
5.8
6.1
6.4
7
MBH
16.2
22
27.8
34.3
41.4
50.2
58.7
68.6
KW
4.5
4.6
4.7
4.8
5
5.3
5.5
6.1
MBH
15.6
21.2
26.7
33
39.8
48.3
56.4
66
KW
4.7
4.8
4.9
5
5.2
5.5
5.8
6.4
MBH
14.4
19.5
24.6
30.4
36.6
44.5
51.9
60.7
KW
4.9
5
5.1
5.2
5.5
5.8
6.1
6.7
1750
1400
55
70
80
55
70
80
55
70
80
55
70
80
55
70
80
70
55
80
70
80
55
70
80
55
70
80
55
70
80
1500
4
2000
2500
1200
1600
OUTDOOR AIR TEMPERATURE, °F (72% RH)
55
5
CFM
RET. AIR °F
Model Tonnage
2000
1050
1200
3