For your safety read before operating, Operating instructions – Whirlpool EDP/EDN User Manual
Page 15
Endurance
Page 15
4.
This appliance is equipped with an ignition
device which automatically lights the burner.
Do not try to light the burner by hand.
5.
Remove control access panel, and top front cover.
6.
Turn gas shutoff valve clockwise
to “off”.
Handle will be horizontal, do not force.
7.
Wait five (5) minutes to clear out any gas. If you
then smell gas, STOP! Follow “B” in the safety
information above on this label. If you don't
smell gas, go to next step.
8.
Turn gas shutoff valve counterclockwise
to
“on”. Handle will be vertical.
9.
Replace top front cover and control access panel.
10. Turn on all electric power to appliance, depress
on/off button on control panel, depress black
button on top of control panel.
11. Set thermostat to desired setting.
12. If the appliance will not operate, follow the
instructions “To Turn Off Gas To Appliance” and
call your service technician or gas supplier.
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING
If you do not follow these instructions exactly, a fire or explosion
may result, causing property damage, personal injury or loss of life.
A. This appliance does not have a pilot. It is
equipped with an ignition device which
automatically lights the burner. Do not try to light
the burner by hand.
B. BEFORE OPERATING smell all around the
appliance area for gas. Be sure to smell next to
the floor because some gas is heavier than air
and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the
fire department.
C. Turn off gas shutoff valve (located above the
combination gas control) so that the handle is
aligned across the gas pipe. If the handle will
not turn by hand, don't try to repair it, call a
qualified service technician. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has been
under water. Immediately call a qualified service
technician to inspect the appliance and to
replace any part of the control system and any
gas control which has been under water.
OPERATING INSTRUCTIONS
1.
STOP! Read the safety information above on
this label.
2.
Set the thermostat to lowest setting.
3.
Turn off all electric power to the appliance.
TO TURN OFF GAS TO APPLIANCE
1.
Set the thermostat to lowest setting.
2.
Turn off all electric power to the appliance if
service is to be performed.
3.
Remove control access panel and top front
cover.
4.
Turn gas shutoff valve clockwise
to “off”. Do
not force.
5.
Replace top front cover and control access
panel.
Combination
Gas Control
Gas Shutoff
Valve