beautypg.com

Wasp Bar Code WWS800 User Manual

Page 20

background image

33

always included in the field. User though, has the option of discarding this
terminating string.

Field Length: The field division can be simply specified by the field length.

The scanner will assign the next specified number of characters into the
field.

9.6 Additional Fields


User can create up to five additional fields for each editing format. Each additional
field can have at most four characters. The additional fields are numbered AF1 to
AF5 accordingly.

9.7 Field Transmission Sequence


After the data fields and the additional fields are configured, user can now program
the transmission sequence of these fields that comprise the final data. The “Start”
label must be read before assigning the field transmission sequence. And then the
desired field transmission sequence can be specified. The scanner will transmit the
fields in the order (sequence) user programmed when sending data. The field
transmission sequence can be assigned in any desired order and fields can also be
assigned multiple times. The maximum number of fields can be assigned is twelve.
After the sequence has been assigned, the “End” label must be read to complete the
setting.

9.8 End of Format Programming


After all the desired parameters are configured, the “End of Format Programming”
label must be read to conclude the programming of the editing format. This label is
located at the bottom of every even page in the “Editing Format Parameters”
section of the configuration manual.

9.9 Activate Data Editing Formats


Before data can be processed by a particular editing format, that format must be
enabled. The editing formats can be enabled or disabled individually.


34

9.10 Exclusive Data Editing


If this parameter is enabled, all data read by the scanner must be processed by the
editing format. If the data is not eligible for all enabled editing formats, the scanner
will not accept the reading and the data will not be transmitted.

9.11 Programming Examples

Example 1: Extracts data from the 10th character to the 19th character.

Total Number of Fields: 3
Field 1: Divide field by field length, set field length to 9
Field 2: Divide field by field length, set field length to 10
Field Transmission Sequence: F2

Example 2: Extract the date code, item number, and quantity information from

barcodes. Data is encoded in the barcode like this: From the first character to the
6th character is the date code. From the 7th character is the item number, its
length is not fixed but is delimited by a ‘-’ character. After the ‘-’ character is the
quantity information.

Data should be transmitted like this: Item number goes first, then a TAB character,
and then the date code, and then another TAB character and finally the quantity.

Total Number of Fields: 3

Field 1: Divide fields by field length and set the field length to 6.
Field 2: Divide fields by field terminating string. Set terminating string to ‘-’,

and discard the terminating string.

Additional Field 1: Set to one TAB character.
Field Transmission Sequence:

F2 AF1 F1 AF1 F3