630-960-0 - pg4-1, Maintenance – Windsor High Speed Burnisher LB2000IA User Manual
Page 13

MAINTENANCE
86309600 (2000) BURNISHER 10/08/08
4-1
MACHINE TROUBLESHOOTING
PROBLEM
CAUSE
SOLUTION
Tripped circuit breaker
Reset
Circuit breaker tripped in
building.
Check and reset
Fuse in motor is blown
Replace
CAUTION: To reduce the risk of
electrical shock, unplug the
machine before opening fuse
holder.
Fuse will only open under extreme
conditions.
Investigate cause before replacing.
Power switch failure
Test switch for continuity and
replace if necessary.
Machine will not run
Faulty power cord
Replace
Equipment not grounded
Follow grounding instructions
exactly.
Receptacle not grounded Have an electrician inspect
building’s wiring.
Electrical shock
Internal wiring problem
Ensure that the machine wiring
matches the appropriate wiring
diagram. Replace any wires or
components, which are short-
circuiting.
Mechanical problem
Higher amp draws indicate a
mechanical problem; find the
problem before using the machine.
Repeated circuit breaker tripping
Faulty circuit breaker
Test circuit for continuity. Replace
circuit breaker if necessary.
Pad not centered
Re-center pad.
Damaged or unevenly
worn pad.
Replace pad. Do not rest machine
on pad when not in use.
Excessive vibration
Damaged pad driver.
Replace.