2. Correct problems found in step #1. If burner

does not fire, press reset button on burner

primary control only once. Repeated presses

will deposit oil in combustion chamber.

Burner must never be fired

when oil is in combustion chamber. Immedi-

ately call qualified service technician.

3. If burner still does not fire, call qualified

service technician.

SGO with probe-type low water cutoff:

1. If burner does not fire, check for:

Service switch on boiler or additional

switches turned off.

Fuses or breaker switch tripped.

Thermostat set below room temperature.

Fuel valves turned off.

Not enough oil in tank to supply burner.

No water in gauge glass.

Start-up

SGO Boiler with Probe-Type Low Water Cutoff

(See Page 5 for Float-Type Low Water Cutoff)