4. Calibration
There are two power-on button combinations to initialize the printer settings and
to calibrate sensors on the W606.
4.1 Printer
Initialization
Printer Initialization will restore printer settings to defaults. Do this if labels are
printing incorrectly and all other solutions have failed to solve the problem.
Default settings:
Item Default
Value
Cleared by
Initialization
Property Saved
when Turning off
Power
Mileage N/A No Yes
Check Sum
N/A
No
Yes
Serial Port
9600,n,8,1
Yes
Yes
Code Page
850
Yes
Yes
Country Code
001
Yes
Yes
Tear Mode
On
Yes
Yes
Peel Mode
Off
Yes
Yes
Cutter Mode
Off
Yes
Yes
Offset 0 Yes Yes
Reference Point
0,0
Yes
Yes
Print Direction
0
Yes
Yes
Speed 4
IPS Yes Yes
Density 08 Yes Yes
Label Size
3”x3” (77X77mm)
Yes
Yes
Gap/Bline Sensor
Gap Sensor
Yes
Yes
Gap(Bline)
0.12” (3 mm)
Yes
Yes
Transparency 17
Yes
Yes
Ribbon Sensor
Sensitivity
1 Yes Yes
LCD Language
English
Yes
Yes
Aux. LED
Off
Yes
Yes
Aux. Buzzer
Off
Yes
Yes
Download Files
N/A
No
Yes
RTC N/A No No