Warning, Electrical requirements – Whirlpool 1187361 User Manual
Page 4
4
NOTE: Cabinet louvers must not be obstructed. Air must be able
to pass freely through the cabinet louvers.
Window installation
Window opening measurements:
■
27 in. (68.6 cm) minimum to 40 in. (101.6 cm) maximum
opening width.
■
19 in. (48.3 cm) minimum opening height.
Electrical Requirements
The electrical ratings for your air conditioner are listed on the
model and serial number label. The model and serial number
label is located on the right-hand side of the cabinet.
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
Recommended ground method
For your personal safety, this air conditioner must be grounded.
This air conditioner is equipped with a power supply cord having
a grounded 3 prong plug. To minimize possible shock hazard, the
cord must be plugged into a mating, grounded 3 prong outlet,
grounded in accordance with all local codes and ordinances. If a
mating outlet is not available, it is the customer's responsibility to
have a properly grounded 3 prong outlet installed by a qualified
electrical installer.
It is the customer's responsibility:
■
To contact a qualified electrical installer.
■
To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 -
latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
1. Cabinet louvers
A. 27 in. (68.6 cm) minimum
B. 19 in. (48.3 cm) minimum
1
A
B
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Do not use an extension cord.
Do not use an adapter.
Do not remove ground prong.
Power supply cord
plug outlet
Wiring requirements
■
115 volt (103.5 min. -
126.5 max.)
■
0-12 amperes
■
15-amp time-delay fuse or
circuit breaker
■
Use on single outlet circuit
only.
■
230 volt (207 min. -
253 max.)
■
0-12 amperes
■
15-amp time-delay fuse or
circuit breaker
■
Use on single outlet circuit
only.
1
/
4
"
(0.6 cm)