MACHINE TROUBLESHOOTING – DELUXE CONTROLLER FAULT CODES


86037660 CHARIOT 05/27/08

4-31

ERROR

CODE

DELUXE

PROBLEM

SOLUTION

None

LCD display on, but incomplete

Disconnect batteries and wait 1 minute before
re-applying power.

0A01

Power down error

Disconnect batteries and wait 1 minute before
re-applying power.

0204

Memory corrupt

Replace controller.

All 080_ codes

Throttle wiring

Check for short or open circuits in throttle
wiring.

All 140 _ Codes

Check for short circuit between B+ and
traction output.

All 310_ Codes

Possible short circuit of motors, auxiliary
outputs (headlight, recycle pump, or back-
up alarm), wiring or damaged controller

Check for short circuits. If code is present
after short circuits are repaired, replace
controller.

7500

LCD module communications timeout

Wiring fault on 6-way serial link between
controller and display.

7501

LCD module settings corrupt

Disconnect batteries and wait 1 minute before
re-applying power.

All 760_ Codes

Brush motor or brush circuit fault

Check for short or open circuits in brush
motors or wiring.

All 770_ Codes

Vacuum motor or vacuum circuit fault

Check for short or open circuits in vacuum
motor(s) or wiring.

7800

Traction motor open circuit fault

Check for open circuit on propel motor or
wiring.

7801

Traction motor overcurrent error

Check for short circuit on propel motor or
wiring.

7802

Traction motor in power foldback state

Propel motor current has exceeded current
limit for the foldback time.

All 790_ Codes

Emergency stop error

E-stop input active or wiring fault.

9000

Brush current requirement not satisfied

Check that brushes or pads are installed.
Check for open circuit in scrub lift actuator,
circuit breaker or wiring.