Page 58: Lcd display on, but incomplete, Power down error, Memory corrupt, Throttle wiring, Lcd module communications timeout, Lcd module settings corrupt, Brush motor or brush circuit fault
MACHINE TROUBLESHOOTING – DELUXE CONTROLLER FAULT CODES
86037660 CHARIOT 05/27/08
4-31
ERROR
CODE
DELUXE
PROBLEM
SOLUTION
None
LCD display on, but incomplete
Disconnect batteries and wait 1 minute before
re-applying power.
0A01
Power down error
Disconnect batteries and wait 1 minute before
re-applying power.
0204
Memory corrupt
Replace controller.
All 080_ codes
Throttle wiring
Check for short or open circuits in throttle
wiring.
All 140 _ Codes
Check for short circuit between B+ and
traction output.
All 310_ Codes
Possible short circuit of motors, auxiliary
outputs (headlight, recycle pump, or back-
up alarm), wiring or damaged controller
Check for short circuits. If code is present
after short circuits are repaired, replace
controller.
7500
LCD module communications timeout
Wiring fault on 6-way serial link between
controller and display.
7501
LCD module settings corrupt
Disconnect batteries and wait 1 minute before
re-applying power.
All 760_ Codes
Brush motor or brush circuit fault
Check for short or open circuits in brush
motors or wiring.
All 770_ Codes
Vacuum motor or vacuum circuit fault
Check for short or open circuits in vacuum
motor(s) or wiring.
7800
Traction motor open circuit fault
Check for open circuit on propel motor or
wiring.
7801
Traction motor overcurrent error
Check for short circuit on propel motor or
wiring.
7802
Traction motor in power foldback state
Propel motor current has exceeded current
limit for the foldback time.
All 790_ Codes
Emergency stop error
E-stop input active or wiring fault.
9000
Brush current requirement not satisfied
Check that brushes or pads are installed.
Check for open circuit in scrub lift actuator,
circuit breaker or wiring.