MACHINE OPERATION

86037660 CHARIOT 11/09/06

3-17

TO BEGIN SCRUBBING

When operating the machine around people, pay
close attention for unexpected movement. Use
extra caution around children.

Flammable liquids and/or reactive metals can
cause explosions or fire! Do not pick up.

1.

Place left foot on operator presence pedal.
Throttle pedal must be in neutral position.

2.

Turn machine power on.

3.

Check position of Directional Control Switch to
ensure that machine is set to travel in direction
intended.

4.

Press the Drive Reset Switch.

5.

BASIC AND CYLINDRICAL

Lower the squeegee.

Lower the scrub deck to floor.

DELUXE

Press the one-touch switch (#1) on the control
panel. The brush motors will start, the scrub
deck will lower to the light scrub position, the
solution will begin to flow, the squeegee will
lower to the floor and the vacuum motors will
start.

6.

Drive machine forward to begin scrubbing.

NOTE: Shut machine off immediately if water or
foam is expelled from the machine.

7.

Adjust the speed of the machine, solution flow
and scrub brush pressure as necessary.

NOTE: Once solution flow rate is set it is not
necessary to shut off solution when stopping
scrubbing. Solution flow is automatically shut off
when brush motors stop. When brush motors are
activated, flow automatically resumes.

PRIMING PUMP

If the solution system has gone dry or has been
unused for a period of time, it may be necessary to
follow the pump priming procedure.

1.

Fill solution tank.

2.

Loosen, but do not completely remove the
strainer bowl. Solution should flow out of the
strainer. If it does not, check the strainer screen
inside the solution tank. Insure it is clear of
debris. Tighten the strainer bowl.

3.

Disconnect the squeegee hose from the
recovery dome.

4.

Begin normal scrubbing and set the solution flow
to maximum setting. Solution flow should begin
within 2 minutes.

5.

Connect squeegee hose to recovery dome.

6.

Adjust the speed of the machine, solution flow
and scrub brush pressure as necessary.