beautypg.com

White Rodgers 1F95W-71 User Manual

Page 35

background image

35

7.

Why won’t the setpoint temperature go
to the temperature I want?
The highest heating setpoint temperature
you select must be at least 1

°

F lower than

the lowest cooling setpoint temperature you
select (for example, if 70

°

F is your lowest

selected cooling temperature, you cannot
select a heating temperature any higher
than 69

°

F). If such a conflict exists, you

must set the lowest cooling temperature
higher in order to set the heating tempera-
ture higher. To set a lower cooling tempera-
ture, you must select a lower heating tem-
perature. See PROGRAMMING YOUR
THERMOSTAT
.

To correct this, remove the thermostat from
the wall and disconnect the battery. Wait
about two minutes, then reconnect the bat-
tery. The thermostat will revert to the factory
preset program until you reprogram the
thermostat. If you don’t want to reprogram

the thermostat immediately, press

SYSTEM

HEAT - OFF - COOL - AUTO

until OFF is displayed and replace the ther-

mostat on the wall. Then press

SYSTEM

HEAT - OFF - COOL - AUTO

until

HEAT, COOL, etc. is displayed, and press

RUN

PRGM

to begin the factory preset program.

Or you may reprogram the thermostat, then
replace it on the wall.

To prevent further static discharge prob-
lems, touch another object to release static
build-up before touching the thermostat.
See OPERATING YOUR THERMOSTAT.