beautypg.com

4 cleaning of clogged round jet tips, Gm 2000 eac - en – Wagner SprayTech GM 2000 EACF User Manual

Page 18

background image

4.4

Cleaning of clogged round jet tips

1. By means of tip spanner (A),

loosen tip insert (B) by a half turn.

2. Remove tip spanner and briefly pull

trigger. Caution, never spray into
an enclosed vessel.

3. After cleaning the tip retighten.

4.5

Exchange of Aircoat round jet tip insert (EAC round)

1. Remove tip insert (B) with tip span-

ner (A).

2. Fit desired tip insert (acc. to table

7.1) with tip spanner.

4.6

Changing from AirCoat round jet to AirCoat flat jet.

1. Replace paint with cleaning sol-

vent, actuate trigger, and thorough-
ly rinse paint channel.

2. Relieve spray gun and system

pressure.

3. Lock spray gun. Turn locking screw

clockwise until stop. (Look in spray-
ing direction)

4. Unscrew tip nut (C).
5. Remove tip body (D) by means of

pin wrench.

6. Fit tip insert (F) on paint channel

(G).

7. Fit air cap (H) onto fan nozzle (F);

make sure that the pins in the air
cap fit into the grooves in the flat
nozzle.

8. Fit cap ring (I) with air cap (H) onto

spray gun body (E).

9. Adjust desired jet level by means of

air cap horns (X) and tighten cap
ring (I) by hand.

GM 2000 EAC - EN

4.2

C

D

E

F

G

H

I

E

X

Universal spanner

A

B

A

B

This manual is related to the following products: