beautypg.com

Cooking, Dimensions & specifications – Viking VICU105-4B User Manual

Page 3

background image

P L A N N I N G A N D D E S I G N G U I D E

V I K I N G R A N G E . C O M

1 - 8 8 8 - V I K I N G 1

R E V I S E D 4 / 2 8 / 1 1

© 2 0 1 1 V R C — I N F O R M AT I O N S U B J E C T T O C H A N G E

COOKING

Professional Built-In Electric All Induction

30”/36”W. Glass Ceramic Cooktop

18”min.

(45.7 cm)

6”min.

(15.2 cm)

3-1/8

(7.9 c

m)

0”min

.

(0 cm

)

36”min.

(91.4 cm)

36”m

in.

(91.4

cm)

13”max.

(33.0 cm)

Minimum clearances from adjacent
combustible construction
• Above countertop (36” [91.4 cm])
• Sides—6” (15.2 cm)
• Rear—0” (0 cm)
• Within 6” side clearance; wall cabinets

no deeper than 13” (33.0 cm)

• Must be minimum 18” (45.7 cm) above

countertop

• Wall cabinets directly above cooktop

must be minimum 36” (91.4cm) above
the countertop.

1. The cooktop may be installed directly

to existing base cabinets.

2. The cooktop cannot be installed

directly adjacent to sidewalls, tall
cabinets, tall appliances, or other side
vertical surfaces above 36” (91.4 cm)
high. There must be a minimum of 6”
(15.2 cm) side clearance from the
cooktop to such combustible surfaces
above the 36” (91.4 cm) counter
height.

3. Within the 6” (15.2 cm) side clearance

to combustible vertical surfaces above
36” (91.4 cm), the maximum wall
cabinet depth must be 13” (33.0 cm)
and wall cabinets within this 6” (15.2
cm) side clearance must be 18” (45.7
cm) above the 36” (91.4 cm) high
countertop.

4. Wall cabinets above the cooktop must

be a minimum of 36” (91.4 cm) above
the countertop for a full width of the
cooktop. This minimum height
requirement does not apply if a hood
is installed over the cooking surface.

The bottom of the hood should be 30”
(76.2 cm) min. to 36” (91.4 cm) above
the countertop. This would typically
result in the bottom of the hood being
66” (167.6 cm) to 72” (182.9 cm) above
the floor. Refer to the hood installation
instructions for further information.

Warning
The use of cabinets for storage above
the appliance may result in a potential
burn hazard. If a cabinet storage is to be

provided the risk can be reduced by
installing a hood that projects
horizontally a minimum of 5” (12.7 cm)
beyond the bottom of the cabinets.

Important: The electronic components
for the induction elements in the
cooktop need some air circulation. To
ensure long life of electronic
components, it is required that a
minimum of 8” (20.3 cm) open space
remain between the bottom of the
cooktop and any shelf underneath. The
maximum length of the shelf underneath
is 18” (45.7cm). There should be no
partition or shelf directly underneath the
unit. It is also required that the exit air
ports at the rear are not blocked. There
should be a minimum of 1-1/4” (3.2 cm)
space between the exit air ports at the
rear of the unit and any nearby
obstruction, including downdrafts.

Dimensions & Specifications

CLEARANCE DIMENSIONS

This manual is related to the following products: