beautypg.com

Vista 20SE User Manual

Page 4

background image

– 4 –

*

49

SPLIT/DUAL REPORTING

[0]

0 = Disable (Backup report only)

TO PRIMARY PHONE No.

TO SECONDARY PHONE No.

1 = Alarms, Restore, Cancel

Others

2 = All except Open/Close, Test

Open/Close, Test

3 = Alarms, Restore, Cancel

A l l

4 = All except Open/Close, Test

A l l

5 = A l l

A l l

TO PRIMARY PHONE No.

TO PAGING No. * (Secondary)

** A 10-digit code is sent to the pager consisting

6 = All except Open/Close

** Alarms, Open/Close, Troubles

of a 4-digit subscriber number, a 3-digit event code,

7 = All reports

** Alarms, Troubles

and a 3-digit user or zone number.

8 = All reports

* * Alarms, Open/Close, Troubles

See Installation Instructions for an explanation

9 = All except Open/Close

* * A l a r ms , O p e n / Cl o s e f o r

of the 10-digit code.

u s e r s 5 - 2 5 ( u s e r s 5 - 1 6 o r
wi r e l e s s b u t t o n z o n e s 1 0 -
2 5 ) , Tr o u b l e s

* Ca n o n l y b e u s e d i f p r i ma r y r e p o r t i n g f o r ma t i s A d e mc o Co n t a c t I D.

*

50

15 SEC DIALER DELAY (BURG)

† [0]

0 = no; 1 = yes; “0” for UL installations

*

51

PERIODIC TEST REPORT

† [0]

0 = none; 1 = 24 hours; 2 = weekly; 3 = 30 days (Enter Test
Code in field * 64. Reports with Partition 1 subscriber No.)

*

52

TEST REPORT OFFSET

† [2]

0 = 24 hour; 1 = 6 hours; 2 = 12 hours; 3 = 18 hours (Time to 1st
report from programming or downloading).

*

53

SESCOA/RADIONICS SELECT

[0]

0 = Radionics (0–9, B–F reporting); 1 = SESCOA (0–9 only
reporting). Select 0 for all other formats.

† Entry of a number other than one specified will give unpredictable results.

*

56

ZONE ASSIGNMENT/ALARM REPORT CODES

—This field is an interactive mode. Fill in the required

data on the worksheet below (and on next page) and follow the programming procedure in the installation
manual.

ZONES ON CONTROL:

See explanation of headings on next page ·

ZONE

ZONE

ZONE

PART'N ALARM RPT CODE

INPUT

RESPONSE

DESCRIPTION

No.

TYPE

No.

(Hex)

TYPE

TIME

(Zn)

(ZT)

(P)

(RC)

(In)

(RT)

Wired Zone 1*

0

1

HW

Wired Zone 2

0

2

HW

Wired Zone 3

0

3

HW

Wired Zone 4

0

4

HW

Wired Zone 5

0

5

HW

Wired Zone 6

0

6

HW

Wired Zone 7

0

7

HW

Wired Zone 8**

0

8

HW

Expansion Module

0

9

0

5

Both

С

С

Supervision

Duress

9

2

Both

С

С

Console Panic (1 &

*,

or A)

9

5

Both

С

С

Console Panic (3 & #, or C)

9

6

Both

С

С

Console Panic (

*

& #, or B)

9

9

Both

С

С

*

Zone 1 can be used as a 2-wire Fire zone.

**

Zone 8 can be used as a Glassbreak zone.