before Advanced start can be activated.
Timer Mode operation
Activation begins a countdown timer as set in the
How Often? (Hours)
screen of the Adjustments menu (default 3 hours). When the timer
expires the engine starts and the
REMOTE START ACTIVATED
message is
sent to the remote control. When the Remote start runtime expires the
engine shuts off, the
REMOTE START DEACTIVATED
message is sent to the
remote control and the countdown timer restarts. This will repeat as
many times as set in the
How Many? (Starts)
screen of the Adjustments
menu (default 6 starts). Timer Start is exited after the final start.
Smart Start operation
Smart Start uses the “Hours” and “Starts” settings used in Timer Mode
in addition to temperature to automatically start the engine. Activation
begins the countdown timer. When the timer expires the vehicle inte-
rior temperature is checked and, if it exceeds the temperature thresh-
olds as set in the
Low Temp
and
High Temp
screens of the Adjustments
menu, the engine starts and the
REMOTE START ACTIVATED
message is
sent to the remote control. When the Remote start runtime expires the
engine shuts off, the
REMOTE START DEACTIVATED
message is sent to the
remote control and the countdown timer restarts. Smart Start is exited
after the final start.
Note
The vehicle battery voltage is also monitored and if below
10.5 volts the engine will start. The battery threshold can
be changed by an authorized Directed dealer if a higher or
lower threshold is desired.
Temperature Reporting
During Remote start the vehicle interior is checked regularly for tem-