Vivotek PZ7131 User Manual
Page 117
![background image](/manuals/219428/117/background.png)
VIVOTEK - A Leading Provider of Multimedia Communication Solutions
User's Manual - 117
notifyserver
0~31
6/6
Indicate which notification server is scheduled.
One bit represents one application server
(server_i0~i4).
The bit0 (LSB) indicates server_i0.
The bit1 indicates server_i1.
The bit2 indicates server_i2.
The bit3 indicates server_i3.
The bit4 indicates server_i4.
For example, enable server_i0, server_i2 and
server_i4 to be notification server. The
notifyserver value is 21.
reserveamount
15~
6/6
The reserve amount in Mbytes when choose cyclic
recording mechanism.
dest
0~4
6/6
The destination to store the recording data.
“0~4” means the index of network storage.
Group: path
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
encoder1_start
7/7
Specify the http push server is active for stream 1
encoder2_start
7/7
Specify the http push server is active for stream 2
Group: https (product dependent)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
connect
1025 ~ 65535
7/7
Specify the stunnel connect port
enable
6/6
To enable or disable this secure http
policy
6/6
If the value is 1, it will force http connection
redirect to https connection
method
auto,
manual,
install
6/6
auto => Create self-signed certificate
automatically
manual => Create self-signed certificate
manually
install => Create certificate request and install
status
-2 ~ 1
6/6
Specify the https status.
-2=>invalid public key
-1=>waiting for certificated
0=>not installed