beautypg.com

Toshiba MK6017MAP User Manual

Page 80

background image

360014937

Copyright ©2000 Toshiba corporation. All rights reserved.

- 580 -

WORD 54: Number of current cylinders defined by INITIALIZE DEVICE PARAMETERS command

WORD 55: Number of current heads defined by INITIALIZE DEVICE PARAMETERS command

WORD 56: Number of current sectors/track defined by INITIALIZE DEVICE PARAMETERS command

WORD 57-58: Total number of sectors calculated by word 54 - 56

bit31-24 by word 58 bit 7- 0
bit23-16 by word 58 bit 15- 8
bit15- 8 by word 57 bit 7- 0
bit 7- 0

by word 57 bit 15- 8

The power on values for each models are.

Drive Type

[*4] : Word 57 - 58

MK6017MAP

11,733,120(B30880H)

WORD 59:
bit15- 9

Reserved

bit 8

1=bit 7- 0 shows number of sectors for multiple sector operation (multiple sector operation is
enabled by SET MULTIPLE command).

bit 7

0 The number of sectors transferred for XX

H

=Write / Read multiple command with 1 Interrupt

( Current value shall be set by SET MULTIPLE command. The default value is 16 ).

The default value for this WORD is 0110h.

WORD 60-61: Maximum number of sectors that user can access in LBA mode

bit31-24

by word 61 bit 7- 0

bit23-16

by word 61 bit 15- 8

bit15- 8

by word 60 bit 7- 0

bit 7- 0

by word 60 bit 15- 8

The power on values for each models are.

Drive Type

[*5] : Word 60 – 61

MK6017MAP

11,733,120(B30880H)