6 smart read log sector – Toshiba MK6017MAP User Manual
Page 101
![background image](/manuals/216509/101/background.png)
360014937
Copyright © 2000 Toshiba corporation. All rights reserved.
-
601 -
10.8.33.6 SMART Read Log Sector
COMMAND CODE
1 0 1 1 0 0 0 0
REGISTER
REGISTER SETTING
NORMAL COMPLETION
DR
DRIVE No.
no change
CY C24Fh
no
change
HD
no
change
SN
Log Sector Address
no change
SC 01h
00h
FT D5h
no
change
This command returns the indicated log sector contents to the host.
Sector number indicates the log sector to be returned as described in the following Table.
Log Sector
Log sector address
Content
R/W
00h Reserved
RO
01h
SMART error log
RO
02h-05h Reserved
RO
06h
SMART self-test log
RO
07h-7Fh Reserved
RO
80h-9Fh
Host vendor specific
R/W
A0h-FFh Reserved
VS
Key
−
RO –Log is read only by the host.
R/W –Log is read or written by the host.
VS –Log is vendor specific thus read/write ability is vendor specific.
10.8.33.6.1 Error log sector
The following Table defines the 512 bytes that make up the SMART error log sector.
SMART error log sector
Byte Descriptions
0
SMART error log version
1
Error log index
2-91
First error log data structure
92-181
Second error log data structure
182-271
Third error log data structure
272-361
Fourth error log data structure
362-451
Fifth error log data structure
452-453
Device error count
454-510 Reserved
511
Data structure checksum
10.8.33.6.2 Error log version
The value of the SMART error log version byte is set to 01h.
10.8.33.6.3 Error log data structure
An error log data structure shall be presented for each of the last five errors reported by the device. These error
log data structure entries are viewed as a circular buffer. That is, the first error shall create the first error log data