beautypg.com

Digital monitor power management, 12 digital monitor power management – TANDBERG 550MXP User Manual

Page 208

background image

D1372102_T550_MXP_User_Manual

198

5.12 Digital Monitor Power

Management


DMPM is monitor power management applied over the digital DVI interface. TANDBERG
supports DMPM in software F2 and above. Six monitor power states are defined.

Monitor On Power state: Transmitter (TANDBERG codec) and receiver (Monitor) are powered
and active. This power state is equivalent with the DPMS normal mode.

Intermediate Power state: When the codec goes from active to standby, it turns off the DVI
transmitter and the monitor can go from Monitor On

Power state to Intermediate Power state.

Active-off Power state:
The monitor can go from Intermediate Power state to Active-off Power
state when the monitor timer expires.

Non-Link Recoverable Off Power State: The monitor can enter Non-Link Recoverable Off
Power State when the codec is switched off or if the DVI cable is disconnected. This power state
is equivalent to the DPMS

Off (with no DPMS recovery)

state.


Monitor Power Switch Off Power state: This state can be entered when the power switch on
the monitor is toggled to its off position. This state has two sub-states dependent on if the codec
is switched on or off.