1.
Remove the Top Cover Assembly as described in Paragraph 6.5.10.
2.
Disconnect the Battery Board Cable from the Main Board (refer to
Figure 6-17).
3.
Remove the two screws holding the Battery Board and remove the Battery
Board Assembly.
4.
Replacement is the reverse of Steps 1 through 3.
6.5.14 Removing/Replacing Inside Frame Assy. (60x Series)
Use the following procedure to separate the inside frame assembly from the base
assembly:
1.
Remove the Top Cover and Fan Assemblies as described in Paragraphs 6.5.10
and 6.5.11 respectively.
2.
Separate the inside frame assembly from the base assembly as shown in
Figure 6-18.
3.
Replacement is the reverse of Steps 1 and 2.