Issue
POssIBle CAuse(s)
ResOluTION
F1: Blower Running
Status Bad
o
oven power interrupted.
o
verify wall circuit breaker is on.
reset breaker and then power the
oven back on.
o
Place the oven into off State for two
(2) minutes, disconnect the plug for
minimum of two (2) minutes, re-plug
in the oven and and press the oven
on soft key.
F2: Cook
Temperature Low
o
oven power interrupted.
o
Air nozzles on the top of the
cook cavity are clogged.
o
oven door is out of alignment.
o
Defective heater.
o
Blower motor not running.
o
oven not fully warmed-up.
o
verify wall circuit breaker is on.
reset breaker and then power oven
back on.
o
open oven door and verify the air
nozzles on the top of the cook cavity
are clean and not clogged.
o
open and close the door several times
and verify oven door is closed. reset
high-limit located in the bottom left
corner of the oven rear wall.
o
Call Customer Service.*
o
Perform self-test (page 26) and call
Customer Service.*
o
repeat warm-up and allow oven to
idle for five (5) minutes.
F3: Magnetron
Current Low
o
Microwave circuit defective.
o
Perform self-test (page 26) and call
Customer Service.*
F4: Door Monitor
Defective
o
oven door switches are out of
order.
o
Perform self-test (page 26) and call
Customer Service.*
F5: Magnetron Over
Temperature
o
Blockage of cool air into
the oven.
o
rear cooling fan exhaust
guard is clogged.
o
Check for paper towels or anything
that may be obstructing cool air into
the oven.
o
Check rear fan to see if it is free of
debris. Clean as required.
28
MAINTeNANCe ANd TROuBlesHOOTING