Automatic track division, Rec mute function, Automatic track division rec mute function – Tascam CC-222MKII User Manual
Page 31: 5 – recording cds—advanced recording
5 – Recording CDs—Advanced recording
TASCAM CC-222MKII
Owner’s Manual
31
Automatic track division
The trigger level, as set above (“Synchronized
recording” on page 29) can also be used to divide
tracks if the A-TRACK (auto track) function is
enabled.
When this function is enabled, the unit automatically
inserts a track division in the recorded material when:
• recording digitally from MD, CD or DAT, an incre-
ment signal is detected and the sound level rises
above the threshold:
or
• increment signals are unavailable (e.g. analog
recording or digital sources other than MD. CD or
DAT) and the sound level has dropped below the
threshold for more than two seconds, and sound
has re-started:
To enable or disable automatic track division:
1
With a recordable disc inserted, press the
MENU
key repeatedly until
A_TRACK>XX
is shown, where
XX
may be
ON
or
OFF
.
2
Turn the
MULTI DIAL
or use the
SKIP
keys to
change the value as required.
The
A-TRACK
indicator at the top right of the
display lights when the auto track function is
enabled.
3
Press the
RECORD
key.
NOTE
When recording certain types of material (e.g. certain
types of classical music or spoken word) through the
analog connections, since the track divisions are deter-
mined by relative silence, it is possible that spurious
track divisions will be inserted. Under these conditions,
it may be better to use manual track division (“Manual
track division” on page 27).
It is not possible to turn this function on and off when
recording.
However, if recording through a digital connection, the
track number will be incremented only when a track
division signal is received, followed by a rise in volume.
A fall and subsequent rise in volume alone when
recording digitally from CD, MD or DAT is not sufficient
to trigger an automatic track increment.
Rec mute function
The rec mute function allows instant cut-off of the
input signal, and records four seconds of silence on
the disc.
1
While recording is in progress, press the
REC
MUTE
key.
The display shows
REC MUTE
, the meters
stop displaying the current level and the
monitored sound is cut.
2
After about four seconds, the unit enters
record ready mode.
time
level
S_LVL
CD-RW
increments
track
Track increment
from source
time
level
S_LVL
At least 2
seconds
Track
increment
time
level
S_LVL
Track incremented
Track start signal
received
time
level
S_LVL
Long "pause"
in signal, but
track is not
incremented
Digital recording from CD, MD and DAT