02.38.3

User's Guide LDK 4482 - SuperXpander

1-5

Left Panel

70 VA max

5

4

3

2

1

6

1

Triaxial cable connector

Connects the large lens adapter to the base station
and carries all signals and power.

2

Utility outlet fuse

This fuse protects the utility outlet. Replace only with
the same type - T1A/115V or T0.5A/230V.

3

Utility outlet

Supplies power (maximum 70W) at the mains supply
voltage and frequency. (Loading or unloading this
outlet could interrupt camera operation.)

4

Utility outlet power indicator

Lights when power is available at the utility outlet.

5

Script light connector

A 3-pole socket which supplies +12 Vdc (500 mA) for
a script board light. (Script board LDK 6985/15 does
not connect to this socket but to the socket at the rear
of the camera.)

6

Camera triaxial flying lead

Connects the large lens adapter to the camera.