2 unit configuration – Toshiba T300MVi User Manual
Page 42

29
the authentication will remain in effect from that point until all browser windows
are closed.
Figure 16: Administrator Authentication
Table 1: Initial factory-set authentication values
Realm
Username
Password
Realm Applies To
USER user
Blank (i.e. do not
enter a password)
Monitoring capabilities
ADMIN admin
Blank (i.e. do not
enter a password)
All change actions
14.2 Unit Configuration
Before the interface is allowed to activate any of its communication protocols, it
must be configured. This is to ensure that the user has initially confirmed that
the current configuration is what they desire. When the interface requires
configuration, the pop-up window shown in Figure 17 appears whenever the
web server page loads into the web browser. The warning will no longer
appear once a configuration data set has been sent to the interface.
•
If the interface is not configured, all RS232, RS485 and Ethernet-based
control protocols are disabled. The web (HTTP) interface, however, can
still be used to read/write information from/to the drive.
•
Even if the unit’s factory-default point configuration is to be used, the
“submit” button (refer to section 14.10) must still be clicked to confirm this
configuration to the interface and activate the Ethernet and serial control
protocols.
•
If the RS232 serial console is selected (refer to section 13.1.2), the console
will operate regardless of the interface’s configuration status.