5 connecting units to power – Transition Networks STACKMASTER TR SMHB-TR-16 User Manual
Page 24
![background image](/manuals/211885/24/background.png)
3.5 Connecting Units to Power
The StackMaster™TR 16-Port Stack is connected to power by connecting
each of the StackMaster™TR 16-Port Units to power.
NOTE: Connect StackMaster™TR 16-Port Units from bottom to top.
To connect the StackMaster™TR 16-Port Stack to power:
1.
At StackMaster™TR 16-Port Unit back, locate the Unit power
receptacle and associated fuse.
NOTE: Fuse must be installed at correct setting for power source voltage
before connecting to AC outlet.
2.
Verify that fuse is installed at correct setting for power source
voltage.
NOTE: The installed fuse rating is indicated by the reading at lower right
corner of fuse holder.
If not installed at correct setting for power source voltage:
•
Carefully open fuse receptacle, using a small flat blade
screwdriver.
•
Rotate fuse holder 180° to the correct rating orientation.
•
Install fuse holder in correct rating orientation.
•
Close fuse receptacle.
3.
Plug unit end (female) of power cord into StackMaster™TR 16-
Port Unit power receptacle.
4.
Plug outlet end (male) of power cord into correct voltage AC wall
socket.
5.
At StackMaster™TR 16-Port Unit front, verify that POWER LED is
illuminated.
6.
Repeat steps 1 through 5 until all StackMaster™TR 16-Port Units
have been powered.
StackMasterTR
3-6
110-120
110-120
220-240
220-240
110-120 Orientation
220-240 Orientation
Fuse Holder
Fuse Holder