beautypg.com

Specifications, 1 specifications – Toshiba GF632 User Manual

Page 42

background image


- 41 -

6F8A0883

9. Specifications

The flowmeter specifications and the type specification code used when ordering the flowmeter
are described in this chapter.

9.1 Specifications

Meter size: 1/2", 1", 1 1/4", 1 1/2", 2", 2 1/2", 3", 4", 5", 6", 8", 10", 12", 14", 16", 18", 20" and 24"

(15, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500 and 600 mm)

Measuring range: 0

–1.0

ft/s to 0

32.8

ft/s (0

0.3

m/s to 0

–10

m/s).

0

0.3

ft/s to 0

1.0

ft/s (0

0.1

m/s to 0

0.3

m/s) range is available optionally for meter

size 1/2” to 18” (15 to 450 mm).

Accuracy: (Accuracy when combined with the converter)

< 1/2” to 18”( 15mm to 450 mm ) >

±0.2 % of Rate *

1

*

1

This pulse output error result is established under standard operating conditions at Toshiba's flow
calibration facility, Fuchu Japan. (NIST Traceable).

*

1

Individual meter measurement error may vary up to ±0.5% of Rate at 1.64 ft/s (0.5m/s) or more and
±0.3% of rate ±0.039 inch/s (1mm/s) at 1.64 ft/s or less.

*

1

Current output: plus ± 8µA (0.05% of span).

*

1

Refer to individual calibration data for each individual meter's measurement error.

< 20” to 24” ( 500mm to 600mm ) >

± 0.3 % of Rate *

2

*

2

This pulse output error result is established under standard operating conditions at Toshiba’s flow

calibration facility, Fuchu Japan.

*

2

Individual meter measurement error may vary up to ±0.5 % of Rate at 3.28 ft/s (1.0 m/s) or more

and ± 0.3% of Rate ±0.079 inch/s (2 mm/s) at 3.28 ft/s (1.0 m/s) or less.

*

2

Current output: plus ± 8µA (0.05% of span.)

*

2

Refer to individual calibration data for each individual meter’s measurement error.

Fluid conductivity: 5 µS/cm minimum

Fluid temperature: –20゚C to +100゚C (–4゚F to 212゚F) ・・・FEP

–20゚C to +120゚C (–4゚F to 248゚F) ・・・PTFE

–20゚C to +60゚C (–4゚F to 140゚F) ・・・Polyurethane (PU)

–10゚C to +60゚C (14゚F to 140゚F) ・・・Chloroprene rubber(CR)

Ambient temperature:
–20゚C to + 60゚C (–4゚F to 140゚F)

Storage temperature: –25゚C to +65゚C (–13゚F to 149゚F)

Storage humidity: 10 to 90%RH (no condensation)

Fluid pressure: 0 to 1MPa (0 to 150 psi, or 0 to 10 bar)
(To be within the applicable flange limitation)

This manual is related to the following products: