Voltage regulation
description

Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147

Overvoltage correction

Input voltages between 128 and 147 are reduced by 12%

Undervoltage correction

Input voltages between 83 and 104 are boosted by 14%

LEDS ALARMS & SWITCHES

LED Indicators

2 LEDs indicate power status and overload/check battery status

Alarms

Audible alarm indicates power-failure and overload status

Switches

Combination switch controls on/off power status and self-test operation

SURGE / NOISE SUPPRESSION

UPS AC suppression joule
rating

420

UPS AC suppression
response time

Instantaneous

UPS Dataline suppression

1 line TEL/DSL (1 in / 1 out)

EMI / RFI AC noise
suppression

Yes

PHYSICAL

Installation form factors
supported with included
accessories

Tower; Ultra-compact desktop; Wallmount (using keyhole mounting tabs)

Primary form factor

Desktop

UPS / Power Module
dimensions in primary form
factor (height x width x
depth / inches)

3.5 x 11.2 x 6

UPS / Power Module
dimensions in primary form
factor (height x width x
depth / cm)

8.9 x 28.6 x 15.2

UPS / Power Module weight
(lbs)

11

UPS / Power Module weight
(kg)

5

UPS Shipping dimensions
(height x width x depth /
inches)

4.8 x 13.5 x 8.8

UPS Shipping dimensions
(height x width x depth / cm)

12.1 x 34.3 x 22.2

Shipping weight (lbs)

12

Shipping weight (kg)

5.5

UPS housing material

ABS

ENVIRONMENTAL

Operating Temperature
Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius