beautypg.com

Troubleshooting – Tascam 302mkII User Manual

Page 18

background image

18

TASCAM 302MKII

The following messages are displayed on the tape counter when two or more 302MkII units are in use, one serving
as the master machine and the others as the slave machines, and an error is detected :

Problem

Possible Cause

Solution

Continuous record/play
impossible

REV MODE switch set to

Ä or ä.

Set switch to CONT.

OFF/SLV/MSTR switch set to SLV or
MSTR.

Set switch to the left OFF position.

Poor sound quality

Heads are dirty.

Clean them, as stated above.

Inappropriate DOLBY NR switch
setting.

Set switch to the setting used for
original recording.

Heads are magnetized.

Demagnetize them, as stated above.

Recording impossible

Erase-protection tabs broken off the
cassette.

Cover tab holes with plastic tape.

Error Messages

Display

Problem

Solution

Err2

Commands interrupted somewhere
because of incoherent switch settings

Make settings coherent throughout the
system.

Err3

Incorrect EXT CONTROL connection

Correct connection.

Troubleshooting

This manual is related to the following products: