beautypg.com

Technical specifications, Product highlights – Tyco Ethernet Input Output Controller DCM 150 User Manual

Page 2

background image

PhySicAl

Size
- Board Only

180 x 120 x 20mm

(7.1” x 4.7” x 0.8”)

- Enclosure

460 x 250 x 90mm

(18” x 10” x 3.5”)

Weight
- Board Only 0.1Kg
- Enclosure 5.00kg
Housing

Wall mounting 1.2mm steel enclosure

Colour

Grey

Power
- Board Only:
- Voltage

11 – 15Vdc

- Current
Consumption

300mA (excluding locks

and heads)

Enclosure:
Voltage

220-230 VAC 50/60Hz.

Current
Consumption

450mA (excluding locks and heads)

Backup Battery

Integral charging circuit provided with

enclosure and space battery

(Battery not supplied).

Environmental
- Temperature

-20º to 70°C (-4° to 158°F)

- Humidity

95% non condensing

LED Indicators

Power, Link to host, Comms Tx/Rx, Fault /

Tamper, Lock and Relay Status

FUncTionAliTy

Inputs

* Door Position

* Lock Status

* Exit Push Button

* General Purpose

Inputs continued

Break Glass Sense

Fire Alarm Sense

Power Fail

Tamper

Battery Low (reported internally)

Dedicated Power Fail Input

* = 4 state tamper protected inputs

Outputs

Two 12V or 24V open collector outputs

limited to 1.5A

(Door Lock and External Sounder)

Two Relays rated at 35V@2A

Reader capacity

2 Weigand/Mag Stripe interfaces (data/

data, clock/data)

Configuration

Operational parameters are downloaded

from host computer.

commUnicATion inTERFAcE

To Readers

Weigand/Mag Stripe interface (data/data,

clock/data)

- Connection

2 part screw terminals

To System Host

RS485 multidrop cable runs using copper

wire with maximum length of 1.2km

without repeater

- Connection

2 part screw terminals

PRodUcT codES

DCM/150/105

DCM 150 (Board Only)

DCM/150/101

DCM 150 (Includes enclosure, board &

power supply/battery charger)

CEM Systems Ltd Unit 4 Ravenhill Business Park Ravenhill Road Belfast BT6 8AW Northern Ireland

Tel: +44 (0)28 9045 6767 Fax: +44 (0)28 9045 4535 email: [email protected]

www.cemsys.com

connect to existing read head technology

The DCM 150 is suitable for installations where customers
want to connect existing read head technology to any of CEM’s
intelligent controller products like webEntry or the S9032/
S9064 with AC2000 SE. Unlike the CEM range of card readers the
DCM 150 does not provide local database support for off-line
card validation.

Ease of installation

Visual confirmation of board, relay and comms transmit/receive

status is provided via LEDs allowing easy installation and
simplifying the diagnostic process. An onboard LED provides
visual alerts to help when a number of DCM’s are banked in
close proximity to one another.

High quality connectors simplify the installation process and
allow simple drop in replacement in the event of hardware
failure. Board configuration is achieved via a small number of
jumpers and requires no specialist tools.

PRodUcT highlighTS

CEM/B/040 Rev C

Product specifications and availability is subject to change without notice. Certain product names mentioned herein may be trade names
and/or registered trademarks of their companies.

TEchnicAl SPEciFicATionS