beautypg.com

Technical specifications, Product highlights – Tyco CEM Systems S9032 User Manual

Page 2

background image

TECHNICAL SPECIFICATIONS

PHySICAL
Size

42 x 483 x 233mm (1U x 19” x 9.2”)

Weight

2.6Kg

Housing

19” rackmounted steel enclosure

Colour

Beige

Power

- Voltage

Mains power adapter 100-240Vac

(supplied).

Output voltage 12Vdc @ 2.0A

- Current
Consumption

300mA

- Backup Battery

Internal Lithium Ion battery giving

a minimum of three hours backup time.

Power fail reported to system internally.

Environmental

- Temperature

-10º to 50ºC (14º to 122ºF)

- Humidity

95% non condensing

LED Indicators

Online/Offline, Ethernet connection,

Activity/Status, Power and Heartbeat

FuNCTIONALITy
Inputs

Dedicated Tamper Input

Dedicated Power Fail Input


Reader capacity

Two Optically isolated RS485 multidropped

reader networks, each supporting up to 16

doors (32 readers IN/OUT per port)

Memory

10MB of RAM

28kB Boot Loader ROM

32MB Compact Flash Disk

Database

- Cardholders

Storage of up to 250,000 cards per

controller, with four access levels and time

zone definition pairs per cardholder record.

- Transactions

Up to 250,000 transactions in offline

operation, depending on amount of

cardholders stored.

Configuration

Custom-made Web Browser GUI available

for displaying controller status and

configuration as well as alarm and

transaction displaying. A Telnet client can

also be used for remote diagnostics.

COmmuNICATION INTErFACE
To Card Reader

RS485 multidrop cable runs using copper

wire with maximum length of 1.2km

without repeater

- Connection

RJ45

To System Host

Ethernet 10/100 BaseT

- Connection

RJ45

PrOduCT COdES

DAC/390/032

S9032 Controller

DAC/390/500

Upgrade to S9064

CEM Systems Ltd Unit 4 Ravenhill Business Park Ravenhill Road Belfast BT6 8AW Northern Ireland

Tel: +44 (0)28 9045 6767 Fax: +44 (0)28 9045 4535 email: [email protected]

www.cemsys.com

Onboard database

The S9032 Controller supports its own database of up to
250,000 card records, depending on the record format and the
memory fitted. The records include card numbers, access level
and time zone details.

rack mounted Enclosure

The S9032 Controller comes mounted in a sturdy 19-inch
1U rack-mounted enclosure providing easy integration into
existing server locations. The S9032 Controller can also be
wall mounted with adjustment of the supplied brackets.

Power Failure Capability

The S9032 Controller has its own external power supply and
internal UPS, giving a minimum of three hours normal usage
in the event of mains power failure, thus keeping potential
downtime to a minimum.

reader Networks

The reader networks connect to two RS485 serial ports on the
S9032 Controller. Each port is distributed over four individual
RJ45 cable connections providing ease of installation and
reducing the time required to identify a faulty reader.

System Expansion

The S9032 Controller forms part of the fully scaleable AC2000
integrated access control system. It can be used to monitor
access control on a small system with only a few doors,
or it can form part of a large-scale access control system.
The reader capacity of the S9032 can be readily doubled by
upgrading to a S9064 Controller.

PrODUCT HIgHLIgHTS

CEM/B/043

Product specifications and availability is subject to change without notice. Certain product names mentioned herein may be trade names
and/or registered trademarks of their companies.

This manual is related to the following products: