beautypg.com

Before making service call, Specifications – Toshiba IK-HR1S User Manual

Page 26

background image

26

Items to be checked

Symptom

No picture

䍃 Is power supplied correctly?

䍃 Is the lens iris adjusted correctly?

䍃 Are the camera and video cables connected correctly?

䍃 Is the shutter mode set correctly?

䍃 Is the monitor on, and in working condition?

䍃 Can the monitor (that you are using) accept the HD-SDI signal coming out of the

camera?

Poor color

䍃 Is the monitor adjusted correctly?

䍃 Is the white balance of the camera adjusted correctly?

(in modes other than automatic tracking)

䍃 Is the matrix color correction set correctly?

䍃 Is the illumination sufficient?

8. BEFORE MAKING SERVICE CALL

Power supply

12V DC

㫧10%

Power consumption

Approx. 3.5 W

Image sensor

1/3 inch color CMOS sensor (Rolling shutter)

Output pixels

Horizontal : 1920, Vertical : 1080 (max)

Scanning system

Progressive

Signal system

1080/59.94i, 1080/50i, 720/59.94p, 720/50p

Scan frequency

Horizontal : 33.716 kHz, Vertical : 59.94 Hz (1080/59.94i setting)
Horizontal : 28.125 kHz, Vertical : 50 Hz (1080/50i setting)
Horizontal : 44.955 kHz, Vertical : 59.94 Hz (720/59.94p setting)
Horizontal : 37.500 kHz, Vertical : 50 Hz (720/50p setting)

Sync system

Internal

Sensitivity

F 4 standard (2000 lx, 3000K)

Minimum illumination

8 lx standard (50 IRE, F1.4, gain

㧗18 dB,

gamma setting ON (setting value 0), 3000 K)

Lens mount

C mount

Operating temperature

(32

㫦F)

to 40

0

F to 104

Operating humidity

Less than 90% (non condensing)

Weight

Approx. 150 g (0.33 lbs)

External dimension

44(W) × 44(H) × 78(D) mm (1.73”(W)

㬍㩷1.73”(H) 㬍㩷3.07”(D) ) (excluding protrusions)

Scene file

A, B, C, D, E

White balance

ATW

䋨Automatic tracing white balance䋩, AWB䋨Automatic white balance䋩,

MANUAL

䋨Manual䋩

Gain

MANUAL (Manual), OFF (0 dB)

Output signal

HD-SDI (SMPTE292M), 0.8 V (p-p) standard
75 ohms unbalanced BNC connector

Remote control

Serial data interface (RS-232C)

Design and specifications are subject to change without notice.

9. SPECIFICATIONS