beautypg.com

1 modulation schemes, 1 2 x btl bd (bd mode), 2 2 x btl ad (default: ad mode) – Texas Instruments TAS5727 User Manual

Page 12

background image

Using the EVM Software

www.ti.com

3.5.1

MODULATION SCHEMES

Using The FAULT PIN As An Error Indicator:

The A_SEL_FAULTZ pin is the I

2

C device address select by default. To re-define this pin as an output,

write '1' to bit D1 of reg 0X05. Once re-programmed as output, this pin indicates a fault condition. Output
will go low for Overcurrent (OC) or undervoltage (UVP) error or overtemperature error (OTE) or
overvoltage error

Common Configurations:

1. 2

×

BTL BD Mode

2. 2

×

BTL AD Mode

Note:

AD: AD Modulation-Outputs are 180

°

out of phase

BD: BD Modulation

BTL: Bridge-Tied Load

3.5.1.1

2 X BTL BD (BD mode)

1. Set up the hardware.

2. Select the Input MUX from GDE. In the Properties window, select BD Mode.

3. GDE: Target

>

Connect.

4. Finally uncheck the shutdown box to bring the device out of Shutdown mode, and adjust the Master

Volume as desired.

3.5.1.2

2 X BTL AD (Default: AD mode)

1. Set up the hardware.

2. Select the Input MUX from GDE. In the Properties window, select AD Mode.

3. GDE: Target

>

Connect.

4. Finally uncheck the shutdown box to bring the device out of Shutdown mode, and adjust the Master

Volume as desired.

12

TAS5727 25W Digital Input Amplifier

with EQ and 2-Band DRC

SLOU299

December 2010

Submit Documentation Feedback

Copyright

©

2010, Texas Instruments Incorporated