4-18
DL3800E Inverse Multiplexer User’s Guide — July 9, 2001
4
Figure 4-8
UNIT CONFIGURATION MENU
Table 4-5 Node Configuration Options
Option
Action
Date
Move the highlight bar to Date, and enter a valid date with the format
MM/DD/YY, and press the Enter key.
MM 1-12 month
DD 1-31 date
YY: 0-99 year
Time
Move the highlight bar to Time, and enter a valid time with the format
hh:mm:ss, and press the Enter key.
HH 0-23 hours
MM 0-59 minutes
SS 0-59 seconds
Alarm Enable
This option allows you to ENABLE or DISABLE the DL3800E unit External
Alarms. Highlight ALARM ENABLE and, using the space bar, toggle
between ENABLED and DISABLED until the desired choice appears.
Automatic Backup
This feature allows you to backup the database to the EEPROM
automatically, at certain intervals, or manually. To change the present
backup mode, highlight Automatic Backup, and use the Space Bar to toggle
between the following choices: after every database change, 15 seconds,
30 seconds, 1 minute, five minutes after each change, or Off (must change
manually with Save Configuration).
DIGITAL LINK DL3800E SR 3.00.22 NODE 1: 08/27/00 00:54:47 MAJOR
SELECTED DEVICE ADDRESS: 1.00.000 NAME:
UNIT CONFIGURATION Exit Confirm
DATE: 08/27/00
TIME: 00:54:38
ALARM ENABLE: Disabled
AUTOMATIC BACKUP: 5 minutes after a database change.
FRONT PANEL: On
PERMIT SELECT DEVICE ACCESS FROM REMOTE: No
UNIT NUMBER: 1
UNIT NAME:
SOFT SERIAL #: 1389031127991
HARDWARE REVISION: H SOFTWARE REVISION: 3.00.22 (DOWNLOADED)
MIB REVISION: 1.10 January 10 2000
TERMINAL BAUD RATE: 9600
TERMINAL #BITS AND PARITY: 8 bits, No parity
TERMINAL STOP BITS: 2 bits