beautypg.com

Quatech MPAP-100 User Manual

Page 57

background image

20 DTE Interface Signals

CIRCUIT AB - SIGNAL GROUND

CONNECTOR NOTATION: DGND
DIRECTION: Not applicable

This conductor directly connects the DTE circuit ground to the DCE circuit ground.

CIRCUIT BA - TRANSMITTED DATA

CONNECTOR NOTATION: TXD
DIRECTION: To DCE

This signal transfers the data generated by the DTE through the communication channel
to one or more remote DCE data stations.

CIRCUIT BB - RECEIVED DATA

CONNECTOR NOTATION: RXD
DIRECTION: From DCE

This signal transfers the data generated by the DCE, in response to data channel line
signals received from a remote DTE data station, to the DTE.

CIRCUIT CA - REQUEST TO SEND

CONNECTOR NOTATION: RTS
DIRECTION: To DCE

This signal controls the data channel transmit function of the local DCE and, on a
half-duplex channel, the direction of the data transmission of the local DCE.

CIRCUIT CB - CLEAR TO SEND

CONNECTOR NOTATION: CTS
DIRECTION: From DCE

This signal indicates to the DTE whether the DCE is conditioned to transmit data on the
communication channel.