Standard Concentric Vent Kit Installation Cont.
Figure 6
Figure 7
Elbow Installation :
• Install the flange gasket (F) onto the boiler
outlet as shown in Figure 7.
• Attach the boiler elbow (G) to the outlet of
the boiler using the 4 screws (H).
• Insert the termination exhaust pipe into
the elbow. (Be careful not to damage the
red exhaust gasket)
• Slide the air intake pipe into the elbow so
the intake gasket (D) fits over the elbow
(G).
Intake Pipe Clamp Installation :
Install the intake pipe clamp (C) on the intake
gasket (D) as shown in Figure 8, using
attachment screws (I)
Figure 8
12
Termination Installation :
• Install the wall gaskets (J) on the
termination pipe (A). One gasket from the
inside of the wall and one from the
outside.
• Install the intake gasket (D) on the
termination pipe (A)