Finishing – Quadra-Fire QFP38-NG User Manual
Page 54
Quadra-Fire • QFP38 Series • 4061-300 Rev i • 9/09
54
0 in.
0 in.
0 in.
15 1/2 in.
43 3/8 in.
Wall finishing material
may be combustible - Top
and Sides
High Temperature Sealant (300° F/149° C min.)
Non-Combustible Zone
Figure 14.2 Non-combustible Facing Diagram
A. Facing Material
• The QFP38 is shipped with a metal front upper in
place.
-
The front upper can be removed if replaced with non-
combustible materials. See Section 1.E. for materials
that may be used.
-
Do not cover or replace this non-combustible upper
front with combustible materials.
• The metal front upper may be covered with non-
combustible materials.
-
Locate the slots on each side of the metal front upper
(see Figure 14.1, #1). Loosen the screws.
-
Locate and remove four screws holding the upper to
the fi rebox (see Figure 14.2, #2).
- Slide the front upper towards the back of the fi rebox
1/2 in. (13 mm) as shown in Figure 14.1, #3.
- Tighten the screws on each side of the front upper
(Figure 14.1, #1).
- Replace the four screws to hold the upper to the
fi rebox (Figure 14.1, #2).
- You may now install non-combustible materials to
the face of the front upper.
• Combustible
fi nish wall material may be butted up to the
unit and the front upper.
-
The unit is shipped with door templates attached. The
wall material should go behind the templates and butt
up to the edge of the unit. Refer to Figure 14.2.
• The joints next to the unit should be fi lled with high
temperature sealant.
WARNING! Risk of Fire! DO NOT apply combustible ma-
terials beyond the minimum clearances. Comply with all
minimum clearances to combustibles as specifi ed in this
manual. Overlapping materials could ignite and will inter-
fere with proper operation of doors and louvers.
14
14
Finishing
1. Slot
(Loosen screw each side)
2. Remove
four screws
3. Slide front
upper towards
back of unit.
Figure 14.1 Covering Front Upper