27. Transmitting Error Indications (Trigger Enabled only)

Computer

Command

Function

/Description

Bar Code

Command

(Z7)

START/END

Programming Menu

-[8-

5E

Do not transmit error code

-6F- %

5F

Transmit “BR” for bad

read or no read

-6G-

5G

Transmit “>”

for bad read;

“?” for no read

-6H-

5H

Transmit “>” for bad read

Transmit “?” for no read

-6I-

5I

Transmit “CAN” for bad

read or no read

-6J-

5J

Transmit “CAN”

for bad read or no read

-6K-

28. Print Quality Adjustments

Computer

Command

Function

/Description

Bar Code

Command

(Z7)

START/END

Programming Menu

-[8-

X4

For lower density, poor print

quality bar code, e.g., dot matrix

with voids (low analog gain)

-Y5-

X5

For high density, good print

quality bar code without voids

(high analog gain)

-Y6-

X6

Output data obtained from Low

or High analog gain

-Y7- %

X7

Output data obtained from Low

and High analog gain

-Y8-