beautypg.com

Opticon LPR5627 User Manual

Page 31

background image

Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount

Scanner

Page 27

♦ Good LED after decoding (green, 200 ms).

♦ RS232C (9600 baud, 8, 1, no parity, no handshaking).

Read Rate Mode (U8) - This mode resets all unit parameters to a predefined set of defaults for the

purpose of checking the scanner read rate. When activated, the test result is sent via RS232C and

indicates the ration of the number of successful read to the total number of attempts. The test result is

reported in the following format:

700 d OK: 93.5%

*CODE-39 TEST*

Where:

♦ 700d indicates the number of times the

decoder ran while scanning at 700 scans per

second (the number can be lower than 700

with poor quality barcodes).

♦ 93.5% indicates the percentage of good

reads to total attempts. T

♦ The control character to be output is CR

(0DE carriage return line fed), "ESC[3A"

(cursor 3 line UP).

The predefined defaults are the following:

♦ Reads all barcodes by symbology.

♦ No fixed number of digits defined (32 digits

max.).

♦ Normal scan, multiple scan.

♦ Trigger disabled.

♦ Small and large.

♦ Buzzer 3 KHz, volume max.)

♦ Buzzer after decoding (10 ms).

♦ Good LED after decoding (green 100 ms)

♦ RS232C (9600 bps, 8, 1, np, no handshaking).