Appendix a: troubleshooting, Appendix a: troubleshooting 85 – Omega OMA-P1104 User Manual
Page 99
Appendix A: Troubleshooting
85
b)
Reco
gnition time setting is too long.
a)
Batteries are either incor
rectl
y installed
or drained.
3.
The OMA-P1104 does not
reco
gnize po
w
er f
ailure.
To
v
erify proper batter
y function, unplug the
unit and v
erify continued operation using
batteries onl
y.
If unit ceases to function,
first tr
y reinstalling the batteries. If this is
not successful, replace the batteries. Refer
to Chapter 2, Section 2.4 for complete
instr
uctions.
Repro
g
ram Reco
gnition
T
ime. Set the
Reco
gnition
T
ime to the minimum required
for a monitored condition to become a v
alid
alar
m. If possib
le, test the condition b
y
deliberatel
y creating an aler
t condition.
Refer to Chapter 5, Section 5.3.
a)
Inputs for alar
m are disab
led.
4.
The OMA-P1104 does not
reco
gnize an
y alar
m.
Enab
le the inputs for alar
m. Refer to
Chapter 5, Section 5.2.
b)
Pro
g
rammed Reco
gnition
T
ime is too
long.
Repro
g
ram Reco
gnition
T
ime. Set the
Reco
gnition
T
ime to the minimum required
before a v
alid alar
m occurs. If possib
le, test
the condition b
y
deliberatel
y creating an
aler
t condition. Refer to Chapter 5,
Section 5.9.