The Sensor Menu screen is used to select sensor options.

Sensor Settings Screen 1/5 - Process (Level 5)

The Sensor Process screen shows the processing mode used to convert the incoming raw data to
engineering units.



Sensor Settings Screen 2/5 - Scaling (Level 5)

The Sensor Scaling screen shows the multiplier and offset used to convert the incoming raw data to
engineering units.



Sensor Settings Screen 3/5 - Logging (Level 5)

The Sensor Logging screen shows the multiplier used when logging sensor data and the rate at which that
data is logged.



Sensor Settings Screen 4/5 - Alarm 1 (Level 5)

Sensor Alarm screen 1 shows the trigger and reset levels used to generate an alarm and the duration used
to qualify the alarm. If the sensor gets its data from an Analog input, the duration is used to provide an alarm
delay. If the sensor is a pulse input counter, the logged data is totalised over the duration before comparing
to the alarm trigger and reset levels.



SENSOR MENU
>Settings
Calibration
Data

SCALING 2/5
x 0.0010
+ 0.0000

LOGGING 3/5
X 00100
∆(min) 00030

ALARM#1 4/5
/ 6.3500
\ 6.5000
∆(min) 00000

+/-

Move down/up through menu

Enter

Select menu item

Alt Enter

Move up to Sensor Status screen

+/-

Move forwards/backwards through sensor setting screens.

Alt Enter

Move up to Sensor Status screen

+/-

Move forwards/backwards through sensor setting screens.

Alt Enter

Move up to Sensor Status screen

+/-

Move forwards/backwards through sensor setting screens.

Alt Enter

Move up to Sensor Status screen

PROCESS 1/5
Mode
Instant

+/-

Move forwards/backwards through sensor setting screens.

Alt Enter

Move up to Sensor Status screen