2 lcd & keypad (iris 320 only), 1 lcd operation, 2 status icons – Optiquest iRIS 320 User Manual
Page 44: 3 keypad buttons
iRIS 220 / iRIS 320, V1.19 User Guide - 42
42
iQuest (NZ) Ltd - PO Box 15169, Hamilton, New Zealand Tel: +64 7 857-0810 Fax: +64 7 857-0811 Email: [email protected]
5.2 LCD & Keypad (iRIS 320 only)
5.2.1 LCD Operation
The iRIS 320 LCD is controlled to optimise power consumption. If the display has powered down, the unit is
in a lower power mode and can be woken by pressing any key on the keypad.
After a certain period of no key presses, the display and backlight will power down again, although other
functions continue normally. If the user was logged on (PIN entered), they will be logged off. This version of
software has the timeout period set to 5 minutes.
5.2.2 Status Icons
At the top of the LCD is a row of status icons.
House
Indicates current wireless connection state as given below:
Invisible
Disconnected
Outline
Connecting
Solid
Connected
R
Indicates presence of data in receive buffer
Invisible
No data in receive buffer
Solid
Some data in receive buffer
Envelope
Flashes when an unsolicited call-in is pending or in progress.
D
Indicates presence of data in transmit buffer
Invisible
No data in transmit buffer
Solid
Some data in transmit buffer
Padlock
Indicates current access level
Invisible
logged in
Outline logged out
Solid
secure
Signal
Indicates signal strength.
Only updated when wireless modem is powered up
but GPRS/CDMA-1X session not active.
Spanner
Indicates presence of terminal connection
Invisible
No terminal connected
Solid
Terminal connected
Battery
Indicates current battery charge. The level
indication bars cycle when charging is in progress.
5.2.3 Keypad Buttons
The four keypad buttons are used to navigate through the LCD screens. Their use varies depending upon
the current screen in view; however the key combinations listed below are constant for all screens.
Alt +
Pan display right
Alt -
Pan display left
NOTE: The display has been designed for a maximum of 24 characters per line even though the
actual LCD can only display 12 characters. Using the panning function allows additional text to be
viewed. This is most useful when viewing logged data samples, where the sample date and time
information is off the screen when the display is fully left.