beautypg.com

6 technical specifications – iris 220 – Optiquest iRIS 320 User Manual

Page 10

background image

iRIS 220 / iRIS 320, V1.19 User Guide - 8

8

iQuest (NZ) Ltd - PO Box 15169, Hamilton, New Zealand Tel: +64 7 857-0810 Fax: +64 7 857-0811 Email: [email protected]

2.6 Technical Specifications – iRIS 220


Dimensions:

100mm x 172mm x 40mm (3.93in x 6.77in x 1.57in)

(Excluding connectors)


Mass:

380g (13.4oz)


Power Supply:

External regulated 12V dc power supply or rechargeable sealed lead-acid battery.

Charger Source - External 15-30V dc supply. Supports a directly connected solar
panel (no regulator required).


Power Consumption:

Less than 3mA @ 12V in idle mode and full power save mode selected.
Actual current consumption is dependent on power management mode, wireless
modem state and I/O configuration.


Comms Interfaces:

1x RS232 DB9, 38400 bps, DTE configuration.
1x Integral dual-band (900/1800MHz) GSM/GPRS modem or
Integral single-band (1900MHz) GSM/GPRS modem or
Integral CDMA/CDMA-X modem


Digital I/O:

2 x Digital Inputs
- 30Vdc maximum input, switch to 0Vdc to activate.
- Link selectable for either mechanical (<20Hz) or electronic (<5kHz) switching.

2 x Digital Outputs
- 1 x Switched 12V out (max 300mA)
- 1 x Open-drain pull-down (max 300mA @ 30V)


Analog I/O:

4 x 12 bit uni-polar analog inputs. Range 0-5000mV. Input impedance 98k

.

Referenced to 0V common. Internal measurements available for monitoring are:

Battery Voltage

Supply Voltage

Internal Temperature (

°

C or

°

F)

Received Signal Strength Indication (RSSI)


Logging Memory:

Non-volatile 2MB flash storage of 262,144 time/date stamped data points. Circular
buffer mode (overwrites oldest data when memory is full).
A typical site with 2 parameters logged every 15 minutes plus battery voltage logged
hourly will give 3.3 years of storage before data overwrite occurs.


Clock/Calendar:

Non-volatile with integral lithium back-up battery. Leap year recognition. Accurate to
+/-20 secs month, trimmable via a configuration register.


Mounting:

4 x M4 (3/16”) mounting holes at ends of case.


Environmental:

Storage Temperature: -20

°

C - +85

°

C. (-4

°

F - +185

°

F)

Operating Temperature: -10

°

C - +70

°

C. (14

°

F - +158

°

F)

This manual is related to the following products: