Oregon Scientific Scientific Cable Free Weather Station BAR928 User Manual

Page 7

background image

EN

6

Temperature resolution

: 0.1

°C (0.2°F)

Remote Temperature measurement

Displayed OUT temperature range : -50.0

°C to +70.0°C

(-58.0

°F to 158.0°F)

Proposed operating range

: -5.0

°C to +50.0°C

(23.0

°F to 122.0°F)

Temperature resolution

: 0.1

°C (0.2°F)

Remote unit

Displayed range

: -50.0

°C to +70.0°C

(-58.0

°F to 158.0°F)

Proposed operating range

: -20.0

°C to +60.0°C

(-4.0

°F to 140.0°F)

Temperature resolution

: 0.1

°C (0.2°F)

RF Transmission Frequency

: 433 MHz

No. of Remote unit

: one

RF Transmission Range

: Maximum 30 meters

Temperature sensing cycle

: around 30 seconds

• Relative Humidity Measurement

Indoor relative humidity measurement ranging from 25%RH to
95%RH

• Barometric Pressure Measurement

Pressure measuring range

: 795 to 1050 mb/ hPa

(23.48 to 31.01 inHg)

Pressure sampling cycle

: 15 minutes

• Moon Phase Functions

Moon Phase Scanner Range

: From 1990 to 2089

• Radio Controlled Clock

- Maintime set and synchronized by Radio Signal DCF77 for
Continental/ Central Europe

- user selectable 12 or 24h display with hh : mm ss

- Date Format : Day-Month-Year or Month-Day-Year

- Day of week selectable in 5 language (E, F, D, I, Sp )

- 2-minute crescendo alarm

• Power

Main unit

: use 4 pcs UM-3 or “AA”

1.5V alkaline batteries

Remote sensing unit

: use 2 pcs UM-4 or “AAA”

1.5V alkaline batteries

• Weight

Main unit

: 306 gm

Remote sensing unit

: 100 gm

• Dimension

Main unit

: 182(L) x 133(W) x 28(T)

mm

Remote sensing unit

: 92(L) x 60(W) x 21(T) mm

HOW TO RESET THE UNIT

The RESET button allows you to return all settings to its factory
values. The button is required only when the unit is not operating in
a favorable way, such as in the rare case of a malfunction.

The RESET button is located inside the battery compartment door.
To use the button,

1. Lift open the battery compartment door.

2. Press the button with a blunt stylus.

3. Replace the battery compartment door.

PRECAUTIONS

This unit is engineered to give you years of satisfactory service if
you handle it carefully. Here are a few precautions:

1. Do not immerse the unit in water. If you spill liquid over it, dry

it immediately with a soft, lint-free cloth.

2. Do not clean the unit with abrasive or corrosive materials. They

may scratch the plastic parts and corrode the electronic circuit.

3. Do not subject the unit to excessive force, shock, dust, tempera-

ture or humidity, which may result in malfunction, shorter
electronic life span, damaged battery and distorted parts.

4. Do not tamper with the unit’s internal components. Doing so

will invalidate the warranty on the unit and may cause unnecessary
damage. The unit contains no user-serviceable parts.

5. Only use fresh batteries as specified in the user’s instructions.

Do not mix new and old batteries as the old ones may leak.

6. Always read the user’s instructions thoroughly before operating

the unit.

TIME ZONE AND OFFSET TABLE

SPECIFICATIONS

• Temperature Measurement

Main unit

Indoor Temperature measurement

Displayed IN temperature range : -50.0

°C to +70.0°C

(-58.0

°F to 158.0°F)

Proposed operating range

: -5.0

°C to +50.0°C

(23.0

°F to 122.0°F)

BAR928-E R1 OP