Step Ten

PROGRAMMING

E. Programming Automatic Empty:

After having powered the

switch with the appropriate supply voltage, entered the CAL mode,

selected a relay channel and erased any previously input set points,

follow the below procedure:

1. Stretch the tape measurer out to the appropriate distance in

between the switch and target.

2. Position the switch at the desired HIGH

set point distance defined as the lesser

of the two air gap spaces between the

transducer and the target. Make sure

that the switch is stationary and per-

pendicular to the target before con-

tinuing.

3. Press the HIGH button for the first key-

stroke and the Relay LED will blink

once.

4. Press the LOW button for the second key-stroke and the Relay

LED will blink twice.

5. The Power LED will flash from AMBER to GREEN when the

HIGH set point has been accepted into memory.

6. Position the switch at the desired LOW set point distance defined

as the greater of the two air gap spaces between the transducer and

the target. Make sure that the switch is stationary and perpen-

dicular to the target before continuing.

7. Press the LOW button for the first key-stroke and the Relay LED

will blink three times.

8. Press the HIGH button for the second key-stroke and the Relay

LED will blink four times.

9. The Power LED will flash from AMBER to GREEN when the

LOW set point has been accepted into memory.

10. Press SELECT to program the next relay channel or slide the

RUN/CAL switch RIGHT to exit the CAL mode.

Automatic Empty

Box

Insert

Table

Target

Wall

Tape

Automatic Empty

Programming

High

Set Point

Distance

Low

Set Point

Distance

De-energize

Energize

2

6

Step Eleven

PROGRAMMING

Programming Duplexing Pump Control:

After having powered

the switch with the appropriate supply voltage, entered the CAL
mode, selected relay channel 1 and erased any previously input set
points, follow the below procedure:

1. Stretch the tape measurer out to the appropriate distance in

between the switch and target.

2. Position the switch at the desired HIGH

set point distance defined as the lesser
of the two air gap spaces between the
transducer and the target. Make sure
that the switch is stationary and per-
pendicular to the target before con-
tinuing.

3. Press the HIGH button for the first key-

stroke and the Relay LED will blink
once.

4. Press the LOW button for the second key-stroke and the Relay

LED will blink twice.

5. The Power LED will flash from AMBER to GREEN when the

HIGH set point has been accepted into memory.

6. Position the switch at the desired LOW set point distance defined

as the greater of the two air gap spaces between the transducer and
the target. Make sure that the switch is stationary and perpen-
dicular to the target before continuing.

7. Press the LOW button for the first key-stroke and the Relay LED

will blink three times.

8. Press the HIGH button for the second key-stroke and the Relay

LED will blink four times.

9. The Power LED will flash from AMBER to GREEN when the

LOW set point has been accepted into memory.

10. Press SELECT to program relay channel 2.

11. Position the switch at the desired HIGH HIGH set point distance

defined as the air gap space between the transducer and the target.
Make sure that the switch is stationary and perpendicular to
the target before continuing.

Duplex

Box

Insert

Table

Target

Wall

Tape

Duplex Programming

(Primary)

High

Set Point

Distance

Low

Set Point

Distance

De-energize (All) Low

Energize
(Backup)

High High

Energize

(Primary)

High