4.6. ALTITUDE, PERSONAL AND
UNIT ADJUSTMENT SETTINGS
[AdJ]
The current Altitude and Personal Adjustment Modes
are shown when diving as well as at the surface. If the
mode does not match the altitude or conditions (see
chapter 3.2.4.), it is imperative that the diver enters the
correct selection before diving. Use the Altitude
Adjustment to select the correct altitude mode. Use the
Personal Adjustment to add an extra level of
conservatism. In this setting mode also the desired units
can be selected (metric, m/°C or imperial, ft/°F).
NOTE: New altitude and personal adjustment
selections cannot be made until 5 minutes after a scuba
dive or 2 to 60 seconds after a free/gauge dive
(depending on the sampling rate).
To set the new Altitude, Personal or Unit Adjustments:
1. In the Setting Mode [SET], press S six (6) times to
select the Altitude, Personal and Unit Adjustment Mode
(Fig. 4.15.).
Fig. 4.17. Setting Personal
Adjustment.
Fig. 4.18. Setting metric/imperial
units.