4.3. Ambient Light Immunity

Decoding performance is guaranteed when the range of illumination on a barcode
surface is between zero and the following values:

Incandescent light

3,000 lx

Fluorescent light

3,000 lx

Sunlight 50,000

lx

Figure 1: Ambient light immunity

Conditions

Barcode Sample: OPTOELECTRONICS Test Sample

PCS: 0.9

Resolution: 0.25

mm

Symbology: 9-digit

Code-39

Quiet Zone:

10 mm

N/W Ratio:

1:2.5

Distance: 70

mm

Angle:

α = 0° β = 15° γ = 0°

Curvature:

R = ∞

Power Supply Voltage:

5.0 V

Direct light or specular reflection light from a source should be prevented from entering
the acceptance area.