Opticon OPR 2001 User Manual
Page 9
![background image](/manuals/204360/9/background.png)
Opticon
OPR 2001
Specifications Manual
9
4.3. Ambient Light Immunity
Decoding performance is guaranteed when the range of illumination on a barcode
surface is between zero and the following values:
Incandescent light
3,000 lx
Fluorescent light
3,000 lx
Sunlight 50,000
lx
Figure 1: Ambient light immunity
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
PCS: 0.9
Resolution: 0.25
mm
Symbology: 9-digit
Code-39
Quiet Zone:
10 mm
N/W Ratio:
1:2.5
Distance: 70
mm
Angle:
α = 0° β = 15° γ = 0°
Curvature:
R = ∞
Power Supply Voltage:
5.0 V
Direct light or specular reflection light from a source should be prevented from entering
the acceptance area.