beautypg.com

Reliability, Auto trigger (option) – Opticon OPR 2001 User Manual

Page 37

background image

Opticon

OPR 2001

Specifications Manual



37

14. Reliability

MTBF (Mean Time Between Failures) of this product is 10,000 hours.

The estimate of MTBF is based on standard operation of the product within the recommended
temperature range and without extreme electronic or mechanical shock.

15. Auto Trigger (Option)

The product has an optional auto trigger setting, which starts barcode reading automatically by
using sensor detection. The scanner starts barcode reading after detecting reflection from the
surface when the auto trigger is used.

Auto trigger distance: 50 ±10 mm from the edge of the scanner.

Conditions

Moving Speed:

100 ±10 mm/s (the moving direction is not specified)

Angle:

Skew angle, excluding Pitch Angle and Dead Zone, specified
in section 7.3 Pitch, Skew and Tilt.

Environmental Temperature and
Humidity:

Room temperature and humidity

Environmental Illuminance:

500 to 900 lx

Conditions for the auto trigger:

1. Barcode sheet: OPTOELECTRONICS Test Sheet (white)
Background: OPTOELECTRONICS Test Sheet (black)
2. Barcode sheet: OPTOELECTRONICS Test Sheet (black)
Background: OPTOELECTRONICS Test Sheet (white)

Figure 28: Auto trigger operation