Opticon OPR 2001 User Manual

Page 21

background image

Opticon

OPR 2001

Specifications Manual



21

b) BUSY/READY

The scanner and the host computer notify each other of their state and
whether they can receive data with BUSY/READY through an RTS line. They
can communicate state to each other through a CTS line when

connected as

in the following figure.

Figure 12: Busy/Ready communication

The scanner stays ON (is able to receive data) except during certain parts of
the process, such as receiving data (buzzer command execution), transmitting
data, and menu processing. The scanner checks the CTS line before
transmitting data. When it is ON, the scanner transmits data. When it is OFF,
the scanner waits for it to turn ON within a set time. The scanner will abort
transmission with an error indication (buzzer) when the CTS line is not ON
within a specified period. The Flow Control time-outs are as follows, and the
default setting is “indefinitely“ (I0).

Flow Control Time Out

Menu/Command

Indefinitely I0

100 ms

I1

200 ms

I2

400 ms

I3

Figure 13: Cannot receive command